tML® - FO Trunk Cables MPO

tML® - FO Trunk Cable MPO/MPO 12G50/125µ OM4 LSOH, Crossover, Length: xxx

P/N: TML-MP/MP50I12G4-xxx

Description

The tML® - FO trunk cable is intended for the connection of two tML®- FO Modules.

Technical data

The tML® - FO trunk cable is preterminated with MPO connectors on both ends. The Cable is very slim and flexible. The end faces of the connectors are optimized by means of Lasercleaving and machine polish. The MPO plug has a defined fiber hieght of 1 - 3,5µ. The max. adjacent fiber height difference is 0,2µm and for all fibers 0,3µm. All system components (modules, trunk cables and patch cords) are co-ordinated for the reaching of the performance particularly. The module is marked with sequential serial number and article number.

Cable: Round cable, 3mm, loose tube, LSOH, aqua
Option:
unsensitive ClearCurve® Corning fiber
Connectors: MTP®/MPO Female Push Pull (aqua)
Pin out: Crossover (TIA/EIA-568-B.1 Methode C)
Tests: Interferometer, Insertion Loss, Return Loss and Visual Final Inspection; all measured values are electronically archived
  QS-Managementsystem ISO 9001, ISO 14001 and TL 9000

Optical Performance:
Fiber Type Wavelength IL (dB) typical IL (dB) max. RL (dB) min.
50/125µ OM4

MPO

850nm

≤ 0,17

0,35 25

 

xxx - stands for the cable length in meters (every length available)

P/N Description
TML-MP/MP50I12G4-xxx     tML® - FO Trunk Cable MPO/MPO 12G50/125µ OM4 LSOH, Crossover, Length: xxx